Customer Service
1-828-781-1903


Viking Spas 54381 Circuit Board, VKV502R1(x), Alt Replacement

  • Part Number: 54381
  • Chip Number: VKV502R1(x)
  • Manufactured by: Viking Spas

$245.70

Add to Cart:

Item Number: 22-5097

Click For All Replacements

  • Description
  • Details
  • Reviews
Please read entire page before placing an order.

This money saving alternate replacement is for replacing Viking Spas 54381 circuit boards having a VKV502R1(x) chip number.
Tip: (x) = the last letter of your chip number.

This alternate circuit board will have a different serial number and a different chip number.
If you want to spend more money for a circuit board with the same number, you will need to click on the button (above) for all replacements too see if the original is stocked.
This alternate replacement is made by the same manufacturer with the same durability and quality.
This alternate replacement has been verified as a working replacement.
See below for feature changes or feature loss (if any).
See below for install instructions (if any are needed).
Cross Reference Verification
Step 1 of 2:
Make sure your circuit board's serial number is in this list.
Tip: The circuit board's serial number is on a sticker on the circuit board (this is not the box's number).
Tip: Only the first five digits are need to verify the serial number.
Tip: Sometimes the serial number is shown as P/N (part number).
Tip: The image above shows an example of a serial number sticker.

Serial Numbers:
  • 54381
  • BAL54381
  • 54381-01
Step 2 of 2:
Make sure your circuit board's chip number is in this list.
Tip: The whole chip number is on a sticker located on the circuit board.
Tip: This is a different sticker than the serial number sticker.
Tip: The image above shows an example of a chip number sticker.

Chip Numbers:
  • VKV502R1A
  • VKV502R1B
  • VKV502R1C
  • VKV502R1D
  • VKV502R1E
  • VKV502
  • VKV502R1
  • VKV502R1(x)
Additional Cross Ref., Compatibility & Installation
Installation instructions:
Connect the BLACK W3 wire to the fuse holder mounted inside the control box and then connect the wire on the other side of the fuse holder to"J61 BLK AC" on the alternate replacement circuit board.
(No soldering needed.)
Tip: If "J61 BLK AC" is occupied then use "J62 BLK AC" instead.
Failure to move this wire to the correct location will prevent your system from running properly and may also cause damage to other equipment including this circuit board.

For systems with two jet pumps or an electric air blower set dip switch "A7" to the OFF position.
Tip: It is a good idea to make a note of this adjustment on your wiring diagram's dip switch descriptions (for future reference) .
Tip: The wiring diagram is usually located on the inside of the control box.

Set all other wires and dip switches on the replacement circuit board as per how they are on the old circuit board.
Note: If the new alternate replacement circuit board has a wire that is not on the old circuit board (or visa versa) then just ignore it.

Please note: system start up process can take up to 10 minutes.
Other Replacement Options
For all cross reference replacements of this circuit board:

Click Here

Or contact us if you need help finding or selecting parts.
Control System Box Serial Numbers
This is not required for cross reference verification.

This circuit board is found in the following hot tub control system boxes (but not limited to).

Control System Box Serial Numbers:;
  • 54380
  • 54380-01.
  • 54380-02

  • Part Number: 54381
  • Chip Number: VKV502R1(x)

  • Manufactured by: Viking Spas
  • Item Number: 22-5097


Be the first to write a review.  Write a Review.